Compare

Xsens

Link

Xsens Link is a mocap suit from the Netherlands.

Sources retrieved: (A, B, C)

Applications
Research and development
Indicative price
Not stated

Visit website

Xsens Link full-body inertial motion-capture suit in black Lycra with orange sensor straps and chest-mounted wireless transceiver

Manufacturer's own photo.

Specifications

12 of 15 stated 3 not stated

How to read the figuresShow guideClose
  • not statedNo source
  • noyesStated by a source
  • 0Reported as zero
  • ASource
  • A*Source with a caveat (select it)
  • CERecords only what the manufacturer states regarding CE marking.

Select a source marker for source details and notes.

Performance2/2 disclosed

Sampling rate240Hz
Latency20ms

Physical1/1 disclosed

Weight1,500g3.31lbOur conversion from 1,500 g. The manufacturer does not state an imperial figure itself, so the conversion has no source of its own.

Sensing and connectivity4/4 disclosed

Body sensors17
Sensing principleInertial (IMU)
Wireless range150m492ftOur conversion from 150 m. The manufacturer does not state an imperial figure itself, so the conversion has no source of its own.
CommunicationWi-Fi 6E Wired

Power1/1 disclosed

Runtime480minNote: load condition not stated

Software and integration2/2 disclosed

ROS 2Yes
SDK languagesC++ Python

Commercial0/1 disclosed

Indicative priceNot stated

Compliance & certifications2/4 disclosed

CEYes
FCCYes
ULNot stated
CCCNot stated

Against the field

Each strip holds every device of this type in the guide that states the figure, one bar per group of values. Further right means a larger figure, not a better device. A taller bar means more devices in that group.

Weight

1,500g3.31lbOur conversion from 1,500 g. The manufacturer does not state an imperial figure itself, so the conversion has no source of its own.

4 mocap suits state a weight

Link

0 state a higher figure, 1 a lower one. 2 state only a bound (≥ or ≤) and are not ranked. Log scale: each step along the axis multiplies the value.

Runtime

480minNote: load condition not stated

7 mocap suits state a runtime

Link

1 states a higher figure, 0 a lower one. 5 state only a bound (≥ or ≤) and are not ranked.

Sampling rate

240Hz

7 mocap suits state a sampling rate

Link

0 state a higher figure, 6 a lower one. Log scale: each step along the axis multiplies the value.

Latency

20ms

6 mocap suits state a latency

Link

1 states a higher figure, 0 a lower one. 4 state only a bound (≥ or ≤) and are not ranked. Log scale: each step along the axis multiplies the value.

Body sensors

17

8 mocap suits state a body sensor count

Link

0 state a higher figure, 6 a lower one. 1 more states exactly the same figure.

Wireless range

150m492ftOur conversion from 150 m. The manufacturer does not state an imperial figure itself, so the conversion has no source of its own.

6 mocap suits state a wireless range

Link

0 state a higher figure, 2 a lower one. 3 state only a bound (≥ or ≤) and are not ranked.

Notes

“Xsens Link system is built to run all day, across operators, environments and the full spectrum of human motion, from walking and running to jumping, crawling and climbing stairs.”

Xsens Technologies B.V. is headquartered in Enschede, The Netherlands (“Pantheon 6A + 8A, 7521 PR Enschede, The Netherlands”).

Intended use, per the manufacturer. “Stream full-body motion from operator to humanoid at 240 Hz with 20 ms latency. Fast enough for closed-loop manipulation and whole-body control.”

Sources

One line per source, not per figure: a source has one retrieval date.

  1. Axsens.com/hubfs/Downloads/Manuals/Xsens%20Link%20-%20User%20Manual.pdfSecondary. Retrieved
  2. Bxsens-humanoids.com/products/Main source. Retrieved
  3. Cxsens.com/hubfs/Downloads/Manuals/Robotics_Teleoperation_Pipeline_Guide.pdfSecondary. Retrieved

Wrong or missing data? Tell us

More devices

Same manufacturer

All devices from Xsens

Same type